Previous product
Next product
![]() |
| ||||||||||||||
UsageStrongcoat FHB is resistant to weathering providing a tough, waterproof membrane with crack bridging properties. Strongcoat FHB produces an aesthetically attractive finish and is supplied in a variety of colours (consult our Sales Department for further details). Typical areas of use include car parks, walkways, sewage treatment works, tank bund walls, etc. Strongcoat FHB has excellent resistance towards many of the chemicals commonly used in an industrial environment (consult our Technical Department for further details). Slip resistant finishes can be produced for very demanding situations. Materials Supplied5kg. CoverageApproximately 2m²/ kg / coat at the specified coating thickness. This coverage figure is based on application to a smooth dense surface. Coverage figures will vary according to the texture, porosity and evenness of the surface on which the Strongcoat FHB is being applied. StorageStore at temperatures between 5°C and 30°C. Shelf LifeApproximately 24 months if stored in unopened containers and under good conditions. Technical Information
|
Application InstructionsSURFACE PREPARATION The surface must be clean, dry (less than 75%RH measured by Hygrometer) and free from dust, laitance, oils, paints or other forms of contamination. Grit blasting can be used to remove laitance and surface contamination. Grit blasting should also be undertaken to remove all rust and scale from steel surfaces prior to using Strongcoat FHB (see the DCP Guide to Surface Preparation for further details). For treatment of surfaces containing expansion joints please consult our Technical Department. PRIMING Strongcoat FHB has excellent adhesion to concrete and priming is not normally necessary. If the substrate is particularly porous a priming coat of Strongcoat Primer is recommended. If the substrate has humidity reading greater than 75%, it is recommended that Strongcoat DPM be used prior to coating with Strongcoat Primer. (Please consult the appropriate data sheets for further details). MIXING Strongcoat FHB comprises two components, a Resin and Hardener which are supplied pre-weighed in the correct proportions. Under no circumstances should part mixing be carried out. Taking care to ensure that the bottom and sides are thoroughly scraped, transfer the entire contents of the Hardener container into the Resin container. Using a power whisk attached to a slow speed electric drill, mix for approximately 2 minutes until a uniform consistency is obtained. Never mix Strongcoat FHB by hand as this could lead to areas of uncured material. APPLICATION Once mixing is complete, transfer the contents of the Strongcoat FHB to a roller tray and using a brush or medium-pile simulated sheepskin roller, apply it evenly over the surface to give a smooth continuous film. WORKING TIME Strongcoat FHB has a working time of approximately 20 minutes at 20°C. Never leave the mixed Strongcoat FHB kit to stand for any length of time prior to application, as this will considerably shorten its working time. CLEANING Once mixing and application are complete, tools can be cleaned with a suitable solvent. Cured material can only be removed mechanically. CURING TIME At 20°C, Strongcoat FHB should be allowed to cure for 24 hours prior to opening it to pedestrian traffic. At the same temperature, Strongcoat FHB should be allowed to cure for approximately seven days prior to opening it to vehicular traffic or exposing it to chemical contamination (consult our Technical Department for details of curing times at other temperatures). OVERCOATING The second coat of Strongcoat FHB must be applied no later than 24 hours at 20°C after the first coat has cured. Additionally, the first coat of Strongcoat FHB must not be contaminated prior to applying the second coat. SLIP RESISTANT FINISHES Apply a coat of Strongcoat FHB to the surface and, whilst this is still wet, completely blind it with an appropriate grade of Aggregate (consult our Technical Department for details of Aggregate grades). Allow the coat of Strongcoat FHB to cure for the specified time (see Curing Time) then vacuum off the excess Aggregate. The bound Aggregate is then sealed with a further coat of Strongcoat FHB (consult our Technical Department for details of coverage rates. The coverage rate of Strongcoat FHB will be considerably reduced when using it to seal Aggregates. WORKING CONDITIONS Strongcoat FHB should not be applied at temperatures below 10°C. HEALTH AND SAFETY Consult the appropriate Material Safety Data Sheets prior to using Strongcoat FHB. GENERAL GUIDANCEThis data sheet is for general guidance purposes only and may contain information that is inappropriate for certain conditions of use. Accordingly, all recommendations and suggestions are made without guarantee. Further information is available from our Technical Department. |
Download file
Related products
Connect with Don Construction Products
Don Construction Products Ltd.
Headquarters
Tel: +44 (0) 1440 766360
Fax: +44 (0) 1440 768897





